Containers
STAFF CONTAINERS
STAFF CONTAINERS
![]()
Staff containers for workplace facilities
Staff containers can provide break rooms, changing rooms and other personnel facilities, including on construction sites. The layout depends on the number of users and the activities the space needs to support.
Layout and equipment
Start with the number of people on each shift. The layout may include changing rooms, a dining area, a rest room, lockers and sanitary facilities. State whether separate clean and dirty changing areas are needed.
The existing offer includes an electrical system with lighting, sockets and heating. Window sizes and positions, doors, roller shutters and partition walls can be discussed when preparing the specification. Tell us the expected number of users, preferred room arrangement and any additional equipment needed so we can prepare a suitable quote.
Combine your planning with our sanitary container offer or explore office containers. Contact iContainers about your requirements.
Price and quotation
Compare the room arrangement, lockers and other equipment, insulation, heating and any sanitary zone. Distinguish preparation for connections from the supply and installation of appliances.
When comparing quotations, check the agreed specification and distinguish the container price from transport, unloading, positioning and installation. A reliable quotation requires the location, planned use and equipment list.
Transport and installation
Provide the delivery town and country, gate dimensions, access restrictions and space for unloading. Agree who prepares the ground and utility connections, and which on-site works are included. Delivery arrangements and feasibility are confirmed for the location.
Describe access for the delivery vehicle, the unloading area and utility availability. Agree the ground preparation and the scope of connections between staff and sanitary modules.
Completed projects
View completed projects. Choose an example close to your plans and describe the changes you need. The dimensions, equipment and delivery scope for your own project will be agreed individually.
Manufacturer and references
iContainers manufactures container systems to order. Learn about the company and review customer references. Technical parameters and any component documentation should be checked against the specification of the chosen configuration.
About iContainers · Customer references.
Describe the team size, changing and dining needs, and whether a kitchen or sanitary area is required. Availability and the production schedule will be confirmed in the quotation.
Request a quote. Send the selected example, delivery location, intended use and preferred timing. You can email a plan, sketch or site photographs to kontakt@icontainers.pl.
FAQ
Yes. Sanitary facilities can be included in the same module or connected as a separate sanitary container.
Yes. The room layout, entrances and equipment are planned according to the number of users.
It can be prepared for year-round use with suitable insulation, windows, heating and ventilation.
We agree the delivery and installation scope individually, based on the location, access and foundation conditions. Send the site address and photos of the entrance and placement area so that unloading and the division of work can be agreed.
Tell us how many people work per shift and how many will use the changing rooms, dining area, toilets and showers at the same time. The type of work and any need to separate clean and dirty areas also matter. We use this information to agree the functions and layout; floor area alone does not determine the number of users.
The price depends on the number of modules, room divisions, insulation, installations and equipment. A changing room, dining area and module with toilets and showers each involve a different scope of work. Confirm equipment, transport, unloading, installation and utility connections separately in the quotation.
Send the number of workers per shift, the rooms required, approximate dimensions or available area, location and target date. Include details of water, sewerage and electricity supplies and the planned period of use. Attach a layout sketch or site photos if available.
phone.:
+48 531-241-672
phone.:
+48 535-986-808
e-mail:
kontakt@icontainers.pl
Technical data
| TECHNICAL DATA | |
| DIMENSIONS | – external: 6006 x 2430 x 2850 mm – internal: 5750 x 2150 x 2500 mm |
| STRUCTURE | – steel structure made of 4 mm thick steel sections according to EN 10025-2:2019 / EN 10025-2:2019 / EN 10051-10; – corner posts firmly welded to the floor and roof structure; – all coated with polyurethane paint (RAL 7016); – lifting lugs for handling, |
| ROOF | – 4 mm thick steel sections; – corner reinforcements made of 4 mm metal sheet; – sandwich panel with 100 mm polystyrene core, double laminated with 0.5 mm metal sheetheat transfer coefficient ‘U’ for BAAS-PANEL D roof panels (0.54 to 0.14) [W/m2K];fire classification according to PN-90/B-02851degree of fire spread: NROfire-resistance rating: RE30 for roof; – roof finishing accessories of 0.5 mm sheet; – sealing: 0.5 mm galvanized sheet; – finishes: 0.5 mm coated sheet (RAL 9010); |
| WALLSY | – 100 mm sandwich panel with a polystyrene core; – exterior wall: 0.5 mm micro-corrugated sheet (RAL 9006);- interior wall: 0.5 mm smooth metal sheet (RAL 9010); – perimeter trims of 0.5 mm metal sheet (RAL 9010); – fire classification according to PN-90/B-02851degree of fire spread: NRO fire-resistance rating: E90 for walls, RE30 for roof; |
| FLOOR | – a strip of Z-sections firmly welded together; – insulated with 100 mm mineral wool (λD = 0.044 W/mK according to PN-EN 13162:2013-05), GUM Technical Approval: 68/322/71/2016; – floor sealing with 1 mm galvanized metal sheet; – floor base: 22 mm DURELIS p5 panel; – 2.5 mm vinyl flooring with abrasion resistant coating;DECLARATION OF PERFORMANCE V434,EN ISO 10874 performance classification: 33-42; according to EN 14041:2004/AC:2006; – skirting boards (RAL 9010); |
| DOORS | – 200/80 cm external solid steel door (RAL 7016); – 200/90 cm door with reinforced wood and steel structure with double lock, three bolts and three hinges (RAL 7016); – internal solid doors (RAL 9010); Declaration of Conformity No. 92/02/2014/HP/KOM/DPO for steel doors Building Research Institute Technical Approval No. AT-15-3435/2014 |
| WINDOWS | – Ideal 4000 tilt and turn window (RAL)installation depth: 70 mm Uw coefficient ≤ 1.3 W/m2K; five-chamber profile; – 120 x 120 cm Ideal 4000 tilt and turn window (RAL 7016) – 100 x 100 cm Ideal 4000 tilt and turn window (RAL 7016) – 80 x 100 cm Ideal 4000 tilt and turn window (RAL 7016) – 53 x 56 cm Ideal 4000 tilt window (RAL 7016) – serving window;-RAS137 adaptive external roller shutter(adjusted to the window size) |
| ELECTRICAL SYSTEM | – 5x32A electrical connection Declaration of Conformity No. 21/2019 RoHS Directive 2011/65/EU; Low Voltage Directive 2014/35/EU; Standards: PN-EN 60309- 1:2002/A 1:2009+A2:2013.03 and PN-EN 60309 02:2002/A1:2009+A2:2012; – 12 module surface-mounted switchboardEC DECLARATION OF CONFORMITY No. 34/2011; No. 19/2012 – residual current and overcurrent protectionDeclaration of Conformity (in accordance with ISO/IEC 17050-1) No. 18/03/2017;Compliant with the standards: EN60898-1/03 + A1/04 + A11/05 + A12/08 + A13/12 ;Low Voltage Directive 2014/35/EU; RoHS Directive 2011/65/EU – LED lamp; – double hermetic (IP54) sockets Declaration of Conformity No. K-S/170/2010, Standard: PN-EN 60669-1:2006 PN-IEC 60884-1:2006 and – IP54 single-pole switch |
| HEATING | – 2000 W convection heater – gravity ventilation |
| KITCHEN FACILITIES | – base cabinets – 180 cm (80 cm sink cabinet, sink, 60 cm fridge + 40 cm cabinet with a drawer and a worktop); – upper cabinets (80 cm + 60 cm + 40 cm); – single-bowl inset sink with a Deante Tango drainer; – under sink tankless water heater– 3.7 – 5.5 kW |
| SANITARY FACILITIES | – Kerra C-clear freestanding toilet unit; – Koło Idol washbasin with Ferro Rosa single-lever mixer; – a shower enclosure with a shower tray / square shower tray with a curtain and a rain shower; – BOSCH Tronic 2000 electric water heater – 18 kW; – Roca Euret urinal with a drain valve |
| ACCESSORIES | – 2.6 kW HAIER air conditioner with an auxiliary heating function;European legal acts: Low Voltage Directive 2014/35/EU; Electromagnetic Compatibility Directive 2014/30/EU; ROHS: Directive 2011/65/EU of the European Parliament and of the Council on the restriction of certain hazardous substances in electrical and electronic equipment WEEE: Directive 2012/19/EU of the European Parliament and of the Council on waste electrical and electronic equipment. |