Containers
CUSTOM CONTAINERS
CUSTOM CONTAINERS
![]()
Custom containers for individual projects
If a standard layout does not meet your needs, discuss an individual container project with iContainers. We can review the intended use, dimensions, room arrangement and equipment to establish a suitable specification.
Layout and equipment
Provide the intended use, dimensions, room layout, entrances, windows and equipment. A sketch helps assess an individual layout, reception point, catering unit or guard cabin. Technical feasibility is confirmed for the specific project.
Send a description of the project, the planned location and a sketch if you have one. Include the required rooms, entrances, windows and installations. Technical feasibility, dimensions, equipment, price and production timing are confirmed individually before an order is agreed.
For a starting point, explore our office containers and modular containers. Send your project requirements to discuss the next steps.
Price and quotation
Individual modifications, glazing, partitions, installations and finishes determine the quotation. Separate essential requirements from optional additions to compare alternatives.
When comparing quotations, check the agreed specification and distinguish the container price from transport, unloading, positioning and installation. A reliable quotation requires the location, planned use and equipment list.
Transport and installation
Provide the delivery town and country, gate dimensions, access restrictions and space for unloading. Agree who prepares the ground and utility connections, and which on-site works are included. Delivery arrangements and feasibility are confirmed for the location.
Send site photographs and access information. Agree ground preparation, utility availability and the delivery and installation scope before ordering.
Completed projects
View completed projects. Choose an example close to your plans and describe the changes you need. The dimensions, equipment and delivery scope for your own project will be agreed individually.
Manufacturer and references
iContainers manufactures container systems to order. Learn about the company and review customer references. Technical parameters and any component documentation should be checked against the specification of the chosen configuration.
About iContainers · Customer references.
Describe the individual function, room arrangement and equipment. Email a sketch and identify the changes needed. Availability and the production schedule will be confirmed in the quotation.
Request a quote. Send the selected example, delivery location, intended use and preferred timing. You can email a plan, sketch or site photographs to kontakt@icontainers.pl.
FAQ
Dimensions, room layout, windows, doors, installations, facade and equipment can be adapted.
Yes. We review a plan, functional description or sketch and agree on feasible technical solutions.
Yes. Modules can be combined into larger buildings tailored to the investment.
Send the intended use, dimensions, equipment, location and required completion date.
phone.:
+48 531-241-672
phone.:
+48 535-986-808
e-mail:
kontakt@icontainers.pl
Technical data
| TECHNICAL DATA | |
| DIMENSIONS | – external: 6006 x 2430 x 2850 mm – internal: 5750 x 2150 x 2500 mm |
| STRUCTURE | – steel structure made of 4 mm thick steel sections according to EN 10025-2:2019 / EN 10025-2:2019 / EN 10051-10; – corner posts firmly welded to the floor and roof structure; – all coated with polyurethane paint (RAL 7016); – lifting lugs for handling, |
| ROOF | – 4 mm thick steel sections; – corner reinforcements made of 4 mm metal sheet; – sandwich panel with 100 mm polystyrene core, double laminated with 0.5 mm metal sheetheat transfer coefficient ‘U’ for BAAS-PANEL D roof panels (0.54 to 0.14) [W/m2K];fire classification according to PN-90/B-02851degree of fire spread: NROfire-resistance rating: RE30 for roof; – roof finishing accessories of 0.5 mm sheet; – sealing: 0.5 mm galvanized sheet; – finishes: 0.5 mm coated sheet (RAL 9010); |
| WALLSY | – 100 mm sandwich panel with a polystyrene core; – exterior wall: 0.5 mm micro-corrugated sheet (RAL 9006);- interior wall: 0.5 mm smooth metal sheet (RAL 9010); – perimeter trims of 0.5 mm metal sheet (RAL 9010); – fire classification according to PN-90/B-02851degree of fire spread: NRO fire-resistance rating: E90 for walls, RE30 for roof; |
| FLOOR | – a strip of Z-sections firmly welded together; – insulated with 100 mm mineral wool (λD = 0.044 W/mK according to PN-EN 13162:2013-05), GUM Technical Approval: 68/322/71/2016; – floor sealing with 1 mm galvanized metal sheet; – floor base: 22 mm DURELIS p5 panel; – 2.5 mm vinyl flooring with abrasion resistant coating;DECLARATION OF PERFORMANCE V434,EN ISO 10874 performance classification: 33-42; according to EN 14041:2004/AC:2006; – skirting boards (RAL 9010); |
| DOORS | – 200/80 cm external solid steel door (RAL 7016); – 200/90 cm door with reinforced wood and steel structure with double lock, three bolts and three hinges (RAL 7016); – internal solid doors (RAL 9010); Declaration of Conformity No. 92/02/2014/HP/KOM/DPO for steel doors Building Research Institute Technical Approval No. AT-15-3435/2014 |
| WINDOWS | – Ideal 4000 tilt and turn window (RAL)installation depth: 70 mm Uw coefficient ≤ 1.3 W/m2K; five-chamber profile; – 120 x 120 cm Ideal 4000 tilt and turn window (RAL 7016) – 100 x 100 cm Ideal 4000 tilt and turn window (RAL 7016) – 80 x 100 cm Ideal 4000 tilt and turn window (RAL 7016) – 53 x 56 cm Ideal 4000 tilt window (RAL 7016) – serving window;-RAS137 adaptive external roller shutter(adjusted to the window size) |
| ELECTRICAL SYSTEM | – 5x32A electrical connection Declaration of Conformity No. 21/2019 RoHS Directive 2011/65/EU; Low Voltage Directive 2014/35/EU; Standards: PN-EN 60309- 1:2002/A 1:2009+A2:2013.03 and PN-EN 60309 02:2002/A1:2009+A2:2012; – 12 module surface-mounted switchboardEC DECLARATION OF CONFORMITY No. 34/2011; No. 19/2012 – residual current and overcurrent protectionDeclaration of Conformity (in accordance with ISO/IEC 17050-1) No. 18/03/2017;Compliant with the standards: EN60898-1/03 + A1/04 + A11/05 + A12/08 + A13/12 ;Low Voltage Directive 2014/35/EU; RoHS Directive 2011/65/EU – LED lamp; – double hermetic (IP54) sockets Declaration of Conformity No. K-S/170/2010, Standard: PN-EN 60669-1:2006 PN-IEC 60884-1:2006 and – IP54 single-pole switch |
| HEATING | – 2000 W convection heater – gravity ventilation |
| KITCHEN FACILITIES | – base cabinets – 180 cm (80 cm sink cabinet, sink, 60 cm fridge + 40 cm cabinet with a drawer and a worktop); – upper cabinets (80 cm + 60 cm + 40 cm); – single-bowl inset sink with a Deante Tango drainer; – under sink tankless water heater– 3.7 – 5.5 kW |
| SANITARY FACILITIES | – Kerra C-clear freestanding toilet unit; – Koło Idol washbasin with Ferro Rosa single-lever mixer; – a shower enclosure with a shower tray / square shower tray with a curtain and a rain shower; – BOSCH Tronic 2000 electric water heater – 18 kW; – Roca Euret urinal with a drain valve |
| ACCESSORIES | – 2.6 kW HAIER air conditioner with an auxiliary heating function;European legal acts: Low Voltage Directive 2014/35/EU; Electromagnetic Compatibility Directive 2014/30/EU; ROHS: Directive 2011/65/EU of the European Parliament and of the Council on the restriction of certain hazardous substances in electrical and electronic equipment WEEE: Directive 2012/19/EU of the European Parliament and of the Council on waste electrical and electronic equipment. |