In order to meet the expectations of the contemporary commercial market, ICONTAINERS manufactures commercial containers for both small and large enterprises. We realize the importance of reducing the expenses, especially for start-ups. As your business grows, the containers can be easily expanded with new modules.
Given their practical design and aesthetic appearance, containers manufactured by ICONTAINERS are used as shops, offices, kiosks or various other commercial points. It is not uncommon that the containers are used as independent stands at various fairgrounds.
phone.:
+48 531-241-672
phone.:
+48 535-986-808
e-mail:
[email protected]
Technical data
TECHNICAL DATA | |
DIMENSIONS | – external: 6006 x 2430 x 2850 mm – internal: 5750 x 2150 x 2500 mm |
STRUCTURE | – steel structure made of 4 mm thick steel sections according to EN 10025-2:2019 / EN 10025-2:2019 / EN 10051-10; – corner posts firmly welded to the floor and roof structure; – all coated with polyurethane paint (RAL 7016); – lifting lugs for handling, |
ROOF | – 4 mm thick steel sections; – corner reinforcements made of 4 mm metal sheet; – sandwich panel with 100 mm polystyrene core, double laminated with 0.5 mm metal sheetheat transfer coefficient ‘U’ for BAAS-PANEL D roof panels (0.54 to 0.14) [W/m2K];fire classification according to PN-90/B-02851degree of fire spread: NROfire-resistance rating: RE30 for roof; – roof finishing accessories of 0.5 mm sheet; – sealing: 0.5 mm galvanized sheet; – finishes: 0.5 mm coated sheet (RAL 9010); |
WALLSY | – 100 mm sandwich panel with a polystyrene core; – exterior wall: 0.5 mm micro-corrugated sheet (RAL 9006);- interior wall: 0.5 mm smooth metal sheet (RAL 9010); – perimeter trims of 0.5 mm metal sheet (RAL 9010); – fire classification according to PN-90/B-02851degree of fire spread: NRO fire-resistance rating: E90 for walls, RE30 for roof; |
FLOOR | – a strip of Z-sections firmly welded together; – insulated with 100 mm mineral wool (λD = 0.044 W/mK according to PN-EN 13162:2013-05), GUM Technical Approval: 68/322/71/2016; – floor sealing with 1 mm galvanized metal sheet; – floor base: 22 mm DURELIS p5 panel; – 2.5 mm vinyl flooring with abrasion resistant coating;DECLARATION OF PERFORMANCE V434,EN ISO 10874 performance classification: 33-42; according to EN 14041:2004/AC:2006; – skirting boards (RAL 9010); |
DOORS | – 200/80 cm external solid steel door (RAL 7016); – 200/90 cm door with reinforced wood and steel structure with double lock, three bolts and three hinges (RAL 7016); – internal solid doors (RAL 9010); Declaration of Conformity No. 92/02/2014/HP/KOM/DPO for steel doors Building Research Institute Technical Approval No. AT-15-3435/2014 |
WINDOWS | – Ideal 4000 tilt and turn window (RAL)installation depth: 70 mm Uw coefficient ≤ 1.3 W/m2K; five-chamber profile; – 120 x 120 cm Ideal 4000 tilt and turn window (RAL 7016) – 100 x 100 cm Ideal 4000 tilt and turn window (RAL 7016) – 80 x 100 cm Ideal 4000 tilt and turn window (RAL 7016) – 53 x 56 cm Ideal 4000 tilt window (RAL 7016) – serving window;-RAS137 adaptive external roller shutter(adjusted to the window size) |
ELECTRICAL SYSTEM | – 5x32A electrical connection Declaration of Conformity No. 21/2019 RoHS Directive 2011/65/EU; Low Voltage Directive 2014/35/EU; Standards: PN-EN 60309- 1:2002/A 1:2009+A2:2013.03 and PN-EN 60309 02:2002/A1:2009+A2:2012; – 12 module surface-mounted switchboardEC DECLARATION OF CONFORMITY No. 34/2011; No. 19/2012 – residual current and overcurrent protectionDeclaration of Conformity (in accordance with ISO/IEC 17050-1) No. 18/03/2017;Compliant with the standards: EN60898-1/03 + A1/04 + A11/05 + A12/08 + A13/12 ;Low Voltage Directive 2014/35/EU; RoHS Directive 2011/65/EU – LED lamp; – double hermetic (IP54) sockets Declaration of Conformity No. K-S/170/2010, Standard: PN-EN 60669-1:2006 PN-IEC 60884-1:2006 and – IP54 single-pole switch |
HEATING | – 2000 W convection heater – gravity ventilation |
KITCHEN FACILITIES | – base cabinets – 180 cm (80 cm sink cabinet, sink, 60 cm fridge + 40 cm cabinet with a drawer and a worktop); – upper cabinets (80 cm + 60 cm + 40 cm); – single-bowl inset sink with a Deante Tango drainer; – under sink tankless water heater– 3.7 – 5.5 kW |
SANITARY FACILITIES | – Kerra C-clear freestanding toilet unit; – Koło Idol washbasin with Ferro Rosa single-lever mixer; – a shower enclosure with a shower tray / square shower tray with a curtain and a rain shower; – BOSCH Tronic 2000 electric water heater – 18 kW; – Roca Euret urinal with a drain valve |
ACCESSORIES | – 2.6 kW HAIER air conditioner with an auxiliary heating function;European legal acts: Low Voltage Directive 2014/35/EU; Electromagnetic Compatibility Directive 2014/30/EU; ROHS: Directive 2011/65/EU of the European Parliament and of the Council on the restriction of certain hazardous substances in electrical and electronic equipment WEEE: Directive 2012/19/EU of the European Parliament and of the Council on waste electrical and electronic equipment. |